Pycckий EN CN Official WeChat

Scan QR code to pay attention to our BEST and share constructive industry observation, News and technological information!

Parent Company

Better

HOME >> PRODUCTS >> GPR-A200 Gas Pressure Regulator

GPR-A200 Gas Pressure Regulator

For gas transmission, for gas supply to industrial and power plants

For outlet pressure control, inlet or differential pressure control

Suitable for natural gas, other non-aggressive gases on request

Features

High capacity due to axial flow

High range ability and high pressure cuts

Valve sleeves are specially coated to eliminate slip stick

Noise reducing outlet duct and /or internal silencer available

Local position indicator standard

Electric valve-position remote indicator available

Simple design, purely pneumatic operation, robust

Fail to close / fail to open models available

Provided with a noise reducing outlet duct and /or an internal silencer

Technical Data


Function and Strength Acc. to EN 334
Nominal Pressure Class150 ~ Class1500 ( 2MPa - 26MPa)
Nominal Size DN25 ~ DN300 (NPS 1〞 ~ NPS 12〞)
Connections Flanged to ANSI B16.5 RF, RTJ
Temperature Class 2 -29℃~60℃, -46℃~60℃
Max. Operating Pressure PSmax 15MPa (Could be less - acc. to the flange pressure class)
Outlet Pressure Ranges Wd 0.1MPa~11MPa
Accuracy Class AC ±1%(AC1), ±2.5%(AC2.5), ±5%(AC5)
Closing Pressure Category SG 2.5%(SG 2.5), 5%(SG5), 10%(SG10)
Lock-up Pressure Zone SZ 2.5% (SZ2.5)
Min. Required Differential Pressure Between Inlet And Outlet Δp 0.5MPa
EX-protection / Protection Class ExdIIBT4, IP65
Materials Main valve body  A105、A350 LF2
Pilot        Aluminium alloy, Steel
Internal parts    Steel, Aluminium, Brass
Spring       X750, A276, 316
Sealings      NBR,FKM,RPTFE

How the regulator works


Gas pressure regulator is a pressure control device in the pressure regulating system. The Diaphragm Unit (permanently connected to the sleeve) divides the Regulator into two rooms. One of the rooms is connected to outlet pressure, and the other to loading pressure produced by the pilot according to pressure downstream. Due to lack of pressure, the regulator spring acts on the diaphragm unit and closes the sleeve.

The sleeve moves to its open position when the force produced by loading pressure acting on the diaphragm unit becomes greater than the force produced by downstream regulated pressure added to the load of the regulator spring. The sleeve keep station when the two forces are equal under these conditions, downstream pressure is equal to the system’s set value.

Any change in requested flow-rate produces a variation in downstream regulated pressure and the regulator controlled by the pilot opens or closes to deliver the requested flow-rate while keeping downstream pressure uniform.


Valve Design


Pilot Design


Dimensions


Dimensions


 

Connections & Pilot type


 

Pressure sampling point mounting position


As shown in Figure 3 and 4, the gas pressure regulator (PCV) pressure sampling point is 5-8xDN from the working valve (PCV or PV) .

 

Order Type Selection


Type Description

 

Pilot type

 

Other special feature

* For matching the export reducing noise reduction device and internal noise reduction device should be marked as GPR-A200b type. 

Contact Better

BETTER FLUID CONTROL VALVES Tel:+86 22 59699701
Fax:+86 22 22193895
Add:No.11 Guwang Street, Jingbin Industrial Park, Tianjin,China
Sales Hot-line:+86 22 22193891 ext.802, +86 15132685726
Recruitment Hot-line:+86 13903161056
Copyright © 2015-2016 Better